TES-1350A Sound Lever Meter
Standard applied | IEC 651 Type2 |
Range | A LO (Low) - Weighting: 35- 100dB A HI (High) - Weighting: 65-130dB C LO (Low) - Weighting: 35- 100dB C HI (High) - Weighting: 65-130dB |
Resolution | 0.1dB |
Frequency Range | 31.5Hz to 8KHz |
Accuracy | ∮2dB |
Dynamic Range | 65dB |
Frequency Weighting | AC |
Time Weighting | Slow & Fast |
Maximum Hold | Decay < 1dB/3min |
Microphone | Electret condenser microphone |
Calibration | Electrical calibration by using the internal oscillator (1KHz sine Wave at 94dB) |
Auxilitary Output | AC conditioned, 0.65Vrms corresponding to each range step, impedance: 600W DC conditioned, 10mV/dB (nominally) |
Operating Condition | 0oC to 40oC < 80% R. H. |
Storage Condition | -10oC to 60oC < 70% R.H. |
Display | 3 1/2 digitals |
Power Supply | one 9V battery |
Size | 240mm(L)x68mm(W)x25mm(H) |
Weight | 215g |
Accessorie | Instruction Manual, 9V Battery, Carrying Case, Screwdriver, Windscreen. |
GAS LEAK DETECTOR 7201 / 7291 AT A GLANCE
DETECTS METHANE AND PROPANE GAS LEAKAGE ! SINGLE COLOR LED DISPLAY 5-LEVEL LEAK !ALARM AND READY LED !BATTERY LOW INDICATION !AUTO-CALIBRATION WHILE POWERS ON !BUILT IN EARPHONE JACK !FEATURES MUTE FUNCTION !QUALITY SEMI-CONDUCTOR SENSOR !QUICK RESPONSE ( MODEL 7291 ) ! 35-40PPM SENSITIVITY !
FEATURE
|
|
SPECIFICATION | ||||||||||||||||||||||||||||||||||||||||
|
|
DT-8839 Professional High Temperature Infrared Thermometers
This is capable of non-contact (infrared) temperature measurements at the touch of a button. The built-in laser pointer increases target accuracy while the backlight LCD and handy push-buttons combine for convenient, ergonomic operation.
Features:
Accuracy
Assumes ambient operating temperature of 23 to 25 oC (73 to 77oF)
-50oC ~ -20oC (-58oF to -4oF) | ±5oC/+9oF |
-20oC ~ 200oC (-4oF to 392oF) | ±1.5% of reading or ±2ºC(+3.6oF) |
200oC ~ 538oC (392oF to 1000oF) | ±2.0% of reading or ±2.0ºC(+3.6oF) |
538oC ~ 1000oC (1000oF to 1832oF) | ±3.5% of reading or ±5ºC(+9oF) |
Specifications:
Temperature Range |
-50~1000oC(-58~1832oF) |
Display Resolution |
0.1oC(0.1oF) |
Optical Resolution | 50:1 Distance to Spot size |
Basic Accuracy | ±1.5% of reading |
Response Time | Less than 1 second |
Spectral Response | 8~14um |
Emissivity | Digitally adjustable from 0.10 to 1.0 |
Over Range Indication | LCD will show "-0L","0L" |
Polarity |
Automatic (no indication for positive polarity);Minus (-) sign for negative polarity |
Diode Laser |
output<1mW,Wavelength 630~670nm,Class 2(II) laser product |
Operating Temp. |
0 to 50oC(32 to122oF) |
Storage Temp. |
–20 to 60oC(-4 to 140oF) |
Relative Humidity |
10%~90%RH operating, <80%RH storage |
Power Supply |
9V battery,NEDA 1604A or IEC 6LR61,or equivalent |
Weight |
290g (10.2 oz.) |
Size | 220 x 120 x 56mm |
Safety |
"CE" Comply with EMC |
Accessories:
9V battery,English manual,Carrying case and Gift box.
Non-contact Forehead Infrared Thermometer
Model: RC001
It gets the human's temperature 5-15cm from forhead or body. It avoid cross infect when using on different people.
It can get the temperature just in 0. 50 seconds.
No material supplement, and no cross infect. Suitable for repeated using.
You can set the standard temperture. Then hunman's temperature is above setted one, the thermometer will alarm.
Have passed ISO, CE certificate.Operation Condition:
Environmental temperature: 10 centigrade --40 centigrade
Relative humidity: Below 85%
Voltage rating: DC3V (A pair of battery, type: AA)
Size: 159mm(length); 89mm(width); 38mm(height)
Weight: 220g
Mini Unit: 0. 1centigrade
Measurement range: 30. 0centigrade --50. 0centigrade
Consumed power: Below 50mv
Measurement error: In 0. 2centigrade
Measurement distance: 50mm--150mm
Time of auto powering off: 5-second
DT-8806H Body Infrared Thermometer |
Features:
Specifications:
Body Temp range | 30.0 to 43ºC/86ºF to 109ºF |
Surface Temp range |
0 to 60ºC(32ºF to 140ºF) |
Basic Accuracy |
In mode of BODY +0.4ºC/+0.7ºF |
Measuring distance |
5~15CM |
Response Time |
0.5 second |
Over range indication |
LCD will show "HI"/"Lo" |
Polarity | Automatic (no indication for positive polarity); Minus (-) sign for negative polarity |
Emissivity |
0.95 fixed value |
Spectral response |
6~14um |
Power off |
Automatic shut off after 7 seconds, approx. |
Operating Temp. |
0ºC to 50ºC (32ºF to 122ºF) |
Storage Temp. |
-20ºC to 60ºC(-4ºF to 140ºF) |
Relative humidity |
10%~90%RH operating,<80%RH storage |
Power supply |
9V battery,NEDA 1604A or IEC 6LR61,or equivalent |
Note: |
Size(HxWxD): 160x82x42mm
Weight: 177g
Accessories:
9V battery, Carrying case, Gift box.