APPA 500 Series Multimeter
APPA 500 Series are all new designed high performance DMMs with 100,000 count extra large display (505) and 20,000 records of data logging capacity. The basic DCV accuracy is up to 0.015% (505). Featuring a diversity of functions and features with Automatic selection and sensing function. Such as Auto AC, DC and AC+DC on voltage and current mode with frequency indication, Auto Selection on Capacitance, Ohm, Diode or Continuity. The on screen menu selection and navigator key drive privdes the most user friendly and you may through a way of your manual. The slim compact designed all weather housing with CAT. IV 6000V highest safety rating. Truly a ultimate testing tool.
DAY & NIGHT
BATTERY & FUSE EASY TO REPLACE
Unscrew only one screw to remove battery door for battery replacement and fuse replacement, designed for user's convenience without opening the bottom case
OPTICAL INTERFACE
Safe and easy used optical interface to connect to PC for data acquisition. APPA 503 and 505 are self-calibrated in connection with calibrator and PC with calibration software. They also have self-data logging function without connecting to a computer.
ALL-WEATHER HOUSING
Designed for harsh environments with water tight gasket as the seams rotary switch, input terminal and battery cover to keep out of dust, dirt and splashing. They can also take shocks and drops, work anywhere from indoor to outdoor.
EXTRA PROTECTION
Ergonomically designed slim shape protectiv holster that includes a built-in tilt stand, a nail hook, and convenient test lead storage. This holster provides an extra degree of protection and convenience for your meter.
NO-OPTION FULL ACCESSORIES
Ergonomically designed test leads wi th comfort-grip, safety-shrouded, full-sleeve right-angle plug and hard alloy tips for long life. Screw-on insulated alligator clips are standard. Also supplied with a temperature adaptor and bead sensor
An innovativ auto ON/OFF backlit feature give you fulltime display visibility and increased battery life.
SPECIFICATIONS: |
Multiply accuracy digit by 10 in 40,000/100,000 count mode. |
Voltage DC |
APPA 503
Range: 40mV~1000V
Resolution: 0.001mV
Basc Accuracy: +/-(0.03%+2d)
APPA 505
Range: 100mV~1000V
Resolution: 0.001mV
Basic Accuracy: +/-(0.015%+2d)
Input Impedance: 10MOhm
Overload Protection 1000Vrms
|
Voltage AC |
APPA 503
Range: 40mV~1000V
Resolution: 0.001mV
Basc Accuracy: +/-(0.70%+5d)
APPA 505
Range: 100mV~1000V
Resolution: 0.001mV
Basic Accuracy: +/-(0.40%+5d)
Input Impedance: 10MOhm//<100pF
Overload Protection 1000Vrms
Conversion Type: AC+DC True RMS indicating
|
Voltage (AC+DC) |
APPA 503
Range: 40mV~1000V
Resolution: 0.001mV
Basc Accuracy: Same as ACV + 1.0%
APPA 505
Range: 100mV~1000V
Resolution: 0.001mV
Basic Accuracy: Same as ACV + 1.0%
Input Impedance: 10MOhm//<100pF
Overload Protection 1000Vrms
Conversion Type: AC+DC True RMS indicating
|
Current DC |
APPA 503
Range: 4mA~40mA/10A
Resolution: 0.1uA
Basc Accuracy: +/- (0.20%+4d)
APPA 505
Range: 10mA~100mA/10A
Resolution: 0.1uA
Basic Accuracy: +/- (0.10%+4d)
Input Protection: 440mA/1000V & 11A/1000V
DC/AC high energy fuse
|
Current AC |
APPA 503
Range: 4mA~40mA/10A
Resolution: 0.1uA
Basc Accuracy: +/- (0.80%+8d)
APPA 505
Range: 10mA~100mA/10A
Resolution: 0.1uA
Basic Accuracy: +/- (0.70%+8d)
Input Protection: 440mA/1000V & 11A/1000V
DC/AC high energy fuse
|
Current (AC+DC) |
APPA 503
Range: 4mA~40mA/10A
Resolution: 0.1uA
Basc Accuracy: Same as ACA + 1.0%
APPA 505
Range: 10mA~100mA/10A
Resolution: 0.1uA
Basic Accuracy: Same as ACA + 1.0%
Input Protection: 440mA/1000V & 11A/1000V
DC/AC high energy fuse
|
Resistance |
APPA 503
Range: 400Ohms~40MOhms
Resolution: 0.01Ohms
Basc Accuracy: +/-(0.20%+2d)
APPA 505
Range: 1000Ohms~10MOhms
Resolution: 0.01Ohms
Basic Accuracy: +/-(0.025%+2d)
Overload Protection 1000Vrms
|
Continuity Beeper |
< 50Ohms, 2KHz tone buzzer
|
Diode Test |
Open circuit voltage: 3V
|
Frequency Counter |
APPA 503 & 505
Range: 10Hz~4MHz
Resolution: 0.001Hz
Basc Accuracy: +/-(0.002%+1d)
|
%Duty Factor |
APPA 503 & 505
Range: 20%~80%
Resolution: 0.1%
Basc Accuracy: +/-6d(20Hz~10KHz, 5Vp-p)
|
Capacitance |
APPA 503
Range: 40nF~40mF
Resolution: 0.001nF
Basc Accuracy: +/-(0.9%+2d)
APPA 505
Range: 40nF~40mF
Resolution: 0.001nF
Basic Accuracy: +/-(0.8%+2d)
Overload Protection 1000Vrms
|
Temperature |
APPA 503 & 505
Range: -200~1200Celsius degree
Resolution: 0.1Celsius degree
Basc Accuracy: +/-(1.0%+1Celsius degree)
|
|
|
GENERAL: |
|
Sampling rate: |
APPA 503:3times/sec APPA 505:6times/sec |
Overload Indication: |
"OL" or "-OL" |
Lower Battery Indication: |
|
Auto Power Off: |
Selectable from off, 1~60 minutes |
Operating Temp. |
0~50Celsius degree, <=80%R.H. |
Storage Temp. |
-20~60Celsius degree |
Temp. coefficient: |
0.15(Spec.Acc)/Celsius degree,
<18Celsius degree or>28Celsius degree |
Safety: |
IEC61010 and designed to meet UL61010, CAT.IV600V/CAT.III 1000V |
Power Requirement: |
AA size 1.5V X 4 batteries(NEDA 15A or IEC LR6) |
Battery Life: |
100 hours (Alkaline battery) |
Size: |
95mm(W) x 200mm(L) x 51.20mm(H) , Without holster |
Weight: |
620 grams (with holster) |
Accessories: |
Test Leads, Alligator Clips, Temp. adaptor, Bead probe,
Protective Holster, USB cable, WinDMM500 Software,
Magnetic Hanging Kit, Alkaline batteries?(installed) and Manual
|
|