APPA 600 Series Insulation Tester and Multimeter
Simple, Smart and Powerful
APPA 605 and 607 are two well designed insulation tester and insulation multimeter, both of them have extra large LCD with 4000 count and 10000 count display.
All designed with innovative auto sensing backlit to extend extra battery life and Low Pass Filter/High Frequency Rejection feature filtering the harmonics of motors and bypass the noisy of electrical equipments. In addition, ergonomically designed remote test probe for repetitive testing without pressing the TEST button on the Tester/Meter for better convenience.
APPA 605 also featured with Automatic calculation of Polarization Index and Dielectric Absorption Ratio, convenient compare (Pass/Fail)function facilitate your daily work with better efficiency.
APPA 607 is a high performance multimeter featured with simple and smart insulation testing funcition.
Both of APPA 605 and 607 can test up to 20GOhm/22GOhm under testing voltage range as 50V,100V,250V,500V and 1000V with CAT. IV 600V safety standard.
DAY & NIGHT
An innovative auto ON/OFF backlit feature give you fulltime display visibility and increased battery life
INSULATION TESTING
Insulation testing with leakage current display (605) and testing range up 20GOhm with 50V, 100V, 250V, 500V and 1000V DC testing voltage.
LOW PASS FILTER(HIGH FREQUENCY REJECTION)
By pass the noise of electrical equipment for stable reading of measurement.
CONVENIENT REPETITIVE TESTING
Ergonomically designed remote test probe for repetitive testing without pressing the TEST button on Tester/Meter for better convenience.
EXTRA PROTECTION
Ergonomically designed slim shape protective holster that includes a built-in tilt stand, a nail hook, and convenient test lead storage. This holster provides an extra degree of protection and convenience for your meter.
BATTERY & FUSE EASY TO REPLACE
Unscrew only one screw to remove battery door for battery replacement and fuse replacement, designed for user's convenience without opening the bottom case.
SPECIFICATONS |
|
Voltage DC |
APPA 605
Ranges: 600.0V
Best accuracy: +/-(1.0%+5d)
Resolution: 0.1V
Input Impedance: 3MOhms
Overload Protection: 600V rms or DC
APPA 607
Ranges: 100mV~1000.0V
Best accuracy: +/-(0.08.0%+2d)
Resolution: 0.01mV
Input Impedance: 10MOhms
Overload Protection: 1000V rms or DC
|
Voltage AC |
APPA 605
Ranges: 600.0V
Best accuracy: +/-(1.5%+5d) 50Hz~5KHz
Resolution: 0.1V
Input Impedance: 3MOhms//<100pF
Overload Protection: 600V rms or DC
APPA 607
Ranges: 100mV~1000.0V
Best accuracy: +/-(0.9%+3d) 50Hz~5KHz
Resolution: 0.01mV
Input Impedance: 10MOhms//100pF
Overload Protection: 1000V rms or DC
Conversion Type: True RMS indicating
|
Current DC |
APPA 607
Ranges: 100mA~400mA
Best accuracy: +/-(0.2%+2d)
Resolution: 0.01mA
Input Protection: 440mA/1000V DC/AC fuse
|
Current AC |
APPA 607
Ranges: 100mA~400mA
Best accuracy: +/-(1.5%+2d)
Resolution: 0.01mA
Input Protection: 440mA/1000V DC/AC fuse
|
Ohm/
Earth Bond Resistance |
APPA 605
Ranges: 40Ohms~40KOhms
Best accuracy: +/-(1.5%+3d)
Resolution: 0.01Ohm
Overload Protection: 600V rms or DC
APPA 607
Ranges: 1000Ohms~40MOhms
Best accuracy: +/-(0.5%+2d)
Resolution: 0.1Ohm
Overload Protection: 1000V rms or DC
|
Continuity Beeper |
APPA 607
<30Ohm, 2KHz tone buzzer
|
Diode Test |
APPA 607
Open Circuit Voltage: 3V DC
|
Insulation Resistance |
APPA 605
Test Voltage Ranges: 50V, 100V, 250V, 500V, 1000V DC
Resistance Ranges: 0.001MOhms~20GOhms
Best accuracy: +/-(1.5%+5d)
Resolution: 1KOhms
Overload Protection: 600V rms or DC
APPA 607
Test Voltage Ranges: 50V, 100V, 250V, 500V, 1000V DC
Resistance Ranges: 0.001MOhms~22GOhms
Best accuracy: +/-(1.5%+5d)
Resolution: 1KOhms
Overload Protection: 1000V rms or DC
|
Frequency Counter |
APPA 607
Ranges: 10Hz~100KHz
Best accuracy: +/-(0.1%+5d)
Resolution: 0.01Hz
Overload Protection: 1000V rms or DC
|
Capacitance |
APPA 607
Ranges: 10nF~40mF
Best accuracy: +/-(1.2%+2d)
Resolution: 0.001nF
Overload Protection: 1000V rms or DC
|
Tempeature |
APPA 607
Ranges: -200~1200Celsius degree
Best accuracy: +/-(1.0%+1Celsius degree)
Resolution: 0.1Celsius degree
Overload Protection: 1000V rms or DC
|
|
|
GENERAL: |
|
Sampling rate: |
APPA 605: 3times/sec APPA 607: 6times/sec |
Overload Indication: |
"OL" or "-OL" |
Lower Battery Indication: |
|
Auto Power Off: |
20 minutes |
Operating Temp. |
0~50Celsius degree, <=80%R.H. |
Storage Temp. |
-20~60Celsius degree |
Temp. coefficient: |
0.15(Spec.Acc)/Celsius degree,
<18Celsius degree or>28Celsius degree |
Safety: |
IEC61010 and designed to meet UL61010, CAT.IV600V(605)
APPA 607 also has CAT.III 1000V rating. |
Power Requirement: |
AA size 1.5V X 4 batteries(NEDA 15A or IEC LR6) |
Battery Life: |
APPA 605: 1100times/insulation test
APPA 607:80 hours (Alkaline battery) |
Size: |
95mm(W) x 200mm(L) x 51.20mm(H) , Without holster |
Weight: |
630 grams (with holster) |
Accessories: |
Remote Probe, Test Leads, Alligator Clips, Protective
Holster, Magnetic Hanging Kit, Alkaline batteries (installed)
and Manual. APPA 607 also included Temp. adaptor and
Bead Probe. |
|